Definition
Exciting force in this context refers to two related but different quantities: the dynamic force associated with producing a target motion in the vibrating mass, and the centrifugal force generated by the rotating unbalanced masses inside the exciter.
Effective vibrating mass (M_v) is the mass that participates in operating vibration — screen box, decks, screen media, cross members, exciter assemblies and a defined portion of the material carried on the deck.
Static moment (M_s) is the sum of each eccentric mass multiplied by its distance from the rotation axis, expressed in kg·m or kg·cm. It is the geometric property that, combined with speed, determines the generated force.
Target acceleration (K) is the required peak acceleration expressed as a multiple of gravitational acceleration.
Working Principle
The calculation connects two physical relationships and accounts for the machine’s dynamic response.
The force required. Newton’s second law gives F = m × a. For a vibrating screen, the mass is the effective vibrating mass, and the acceleration is K times gravity. The result is the inertial force associated with accelerating the screen body through its motion.
The force generated. A rotating unbalanced mass generates centrifugal force proportional to its mass, its radius from the rotation axis, and the square of angular velocity. Multiple masses acting in the same direction and correctly phased add their contributions.
Why they are not the same calculation. In a spring-supported, damped vibrating system, the applied force and the resulting displacement are related through the system’s dynamic response, not through a simple multiplication. Near resonance, the relationship between force and displacement changes significantly. Spring restoring force, damping, phase relationships, screen-body rotation and coupling between translational and rotational motion all affect how the generated force produces the required motion.
Where the sizing check fits. The calculation gives a preliminary static moment requirement. That static moment must then be matched against the exciter manufacturer’s available working-moment range, bearing load capacity, shaft strength, permissible speed and mounting interface. A preliminary match that satisfies static moment does not automatically satisfy bearing life or structural limits.
Benefits
-
Correct exciter sizing when effective mass and target acceleration are established from validated data.
-
Avoided oversizing when full throughput is not mistakenly included as vibrating mass.
-
Avoided undersizing when amplitude and stroke are correctly distinguished.
-
Cross-check confidence when amplitude measurement confirms the acceleration target.
-
Better supplier conversations when operating data and mass basis are provided.
-
Reduced risk of structural overload when force increase is evaluated against structural limits before adjustment.
Applications
-
Large mining screens in iron ore, copper ore, gold ore and base metal circuits.
-
Aggregate processing screens operating continuously under abrasive duty.
-
Coal preparation where wet screening and variable feed apply.
-
Multi-exciter linear screens where force division and synchronization are critical.
-
Replacement exciter selection where existing operating data provides the basis.
-
Process change evaluation where feed rate, density or stroke has changed.
These duties sit between size reduction in CRUSHING and downstream CLASSIFICATION or DEWATERING. Sizing affects the entire circuit, not only the deck.
Material Comparison
| Property | Inertial Force Calculation | Centrifugal Force Calculation | Cross-Check from Amplitude |
|---|---|---|---|
| Input | Effective mass, target acceleration | Static moment, speed | Measured amplitude, speed |
| Output | Required dynamic force | Force generated by weights | Acceleration as G-force |
| Purpose | Establish the force the screen needs | Establish the force the exciter provides | Verify consistency |
| Common error | Including full throughput as mass | Using stroke as amplitude | Unreliable measurement point |
| When to use | Preliminary sizing | Exciter selection | Post-installation verification |
Application Comparison
| Scenario | Dominant Calculation Issue | Recommended Approach |
|---|---|---|
| New exciter selection | Mass basis not established | Obtain effective mass from design data, not shipping weight |
| Replacement of an existing exciter | Existing speed and moment known | Use nameplate and measured amplitude for verification |
| Amplitude appears low | Stroke vs amplitude confusion | Confirm measurement convention before calculating |
| Process change evaluation | Vibrating mass or duty has changed | Recalculate with new mass and acceleration target |
| Dual exciter balance | Force division assumption | Verify synchronization and phase from the drawing |
| Speed adjustment consideration | Force scales with ω² | Evaluate against structural and bearing limits first |
Industry Application Matrix
| Industry | Typical Screen | Calculation Priority | Common Error |
|---|---|---|---|
| Iron ore | Large heavy-duty screens | Effective mass and target acceleration | Including oversize feed as vibrating mass |
| Copper | SAG discharge screens | Exciter arrangement and speed | Assuming equal force division between exciters |
| Gold | Multi-deck screens | Per-deck mass contribution | Using overall mass for a single deck calculation |
| Coal | Wet screening screens | Material mass contribution | Treating wet material as dry mass |
| Aggregates | Two-deck and three-deck screens | Amplitude and stroke convention | Using stroke as amplitude |
| Sand and gravel | Compact screens | Speed conversion from rpm | Force comparison without ω² conversion |
| Industrial minerals | Fine screens | Acceleration target from design | Using generic K value |
| Base metals | Grinding circuit screens | Bearing and structural verification | Sizing on force alone |
| Phosphate | Wet screens | Effective mass with moisture | Dry mass assumption |
| Tailings | Dewatering screens | Amplitude from commissioning data | Confusing peak-to-peak with single amplitude |
Selection Guide
1. Establish the mass basis. Effective vibrating mass includes screen box, decks, media, cross members, exciter assemblies and the defined material portion. State clearly whether the figure is empty, loaded or design case.
2. Obtain the target acceleration. From screen design or a validated calculation for the specific duty. Do not use a generic K value across applications.
3. Calculate the preliminary required force. F_r = M_v × K × g. Convert newtons to kN for practical sizing.
4. Convert operating speed to angular velocity. ω = 2πn / 60. Force scales with ω², so speed conversion accuracy matters.
5. Calculate required static moment. M_s = F_r / ω². Convert between kg·m and kg·cm carefully — a factor of 100 difference.
6. Account for exciter arrangement. Single versus dual, circular versus linear, phase relationship. Divide force between exciters only after confirming the configuration shares it equally.
7. Cross-check with amplitude. A = S/2 for stroke to amplitude conversion. a = A × ω². Compare K from this calculation with the target K used in step 3.
8. Verify against structural and bearing limits. The static moment must be within the exciter’s working range and the screen’s structural fatigue limits. Force alone is not sufficient selection criteria.
Procurement Guide
Required information: screen brand and model, exciter nameplate details, operating speed, measured amplitude or stroke, mass data from commissioning or design, assembly drawings, failure symptoms where applicable, operating hours and duty.
Drawings needed: exciter assembly drawing showing eccentric weight arrangement and static moment, screen deck drawing showing exciter mounting positions.
OEM part numbers: obtain original references for exciters, weights, bearings and mounting hardware.
Material selection: confirm exciter force rating, speed range, static moment range, bearing specification and mounting interface against the original machine design.
MOQ, lead time, packaging and shipping: confirm lead time against planned maintenance, packaging for heavy components.
Inspection standards: static moment verification against catalogue, bearing verification, speed rating confirmation, dimensional check against mounting interface.
Supplier evaluation checklist — ask directly:
-
Can you supply an exciter matched to our required static moment and speed?
-
Can you provide the static moment and force rating documentation?
-
Can you support OEM replacement for the existing exciter model?
-
Do you have export experience in our region?
-
Can you provide application references for similar screens?
The WHICH MANUFACTURER OFFERS HIGH-QUALITY POLYURETHANE TUFFLEX WIRE SCREENS FOR MINING? guide expands on supplier evaluation.
Failure Analysis
| Problem | Possible Cause | Recommended Solution |
|---|---|---|
| Screen amplitude below target | Exciter static moment too low | Recalculate required static moment and verify exciter |
| Exciter force appears adequate but amplitude low | Spring stiffness or damping issue | Dynamic analysis with complete system model |
| Structural damage after exciter change | Force exceeded structural limit | Verify against structural fatigue analysis |
| Uneven amplitude between exciters | Force division not equal | Check synchronization, phase and weight settings |
| Calculated force much higher than expected | Mass basis included full throughput | Revise mass basis to effective vibrating mass |
| Exciter appears correct but bearings fail early | Bearing load calculation not done | Verify bearing capacity against actual operating load |
| Force calculation mismatch with measured motion | Stroke vs amplitude confusion | Confirm measurement convention and recalculate |
| Amplitude varies by position | Structural flexibility or support issue | Measure at multiple points per OEM specification |
| Vibration at wrong frequency | Speed conversion error | Verify rpm to rad/s conversion |
| Exciter speed limit exceeded | Catalogues use different speed bases | Check manufacturer’s approved speed range |
Maintenance Guide
Commissioning: record effective mass basis, target acceleration, calculated force, measured amplitude and frequency at multiple points for baseline.
Periodic verification: re-measure amplitude and frequency at the same points and conditions. Compare with commissioning baseline.
After any exciter change: recalculate required static moment and verify against the new unit’s specification. Do not assume dimensional similarity indicates suitability.
After mass change: if screen media, liners or other mass-affecting components change, recalculate the vibrating mass and verify exciter remains suitable.
After speed change: force scales with ω², so any speed change requires force recalculation and structural verification.
Documentation: record every calculation, mass basis, speed, amplitude measurement and exciter specification for future reference.
Safety: isolate and lock out before any measurement or adjustment involving the exciter or drive system.
Case Study
Customer Type: Mid-size copper concentrator with a linear-motion screen on a primary sizing duty.
Ore Type: Copper ore with hard angular particles.
Operating Conditions: Original equipment exciter, operating for 6 years without issue. Exciters replaced during planned overhaul with a supplier offering a dimensionally identical unit.
Problem: Within three months of installation, the screen showed reduced throughput and uneven material distribution across the deck. Plant suspected installation error.
Solution: A calculation review was initiated. The original exciter nameplate showed 1,200 rpm operating speed. The replacement was rated at 1,000 rpm — dimensionally identical but with different speed rating. At 1,000 rpm, ω = 104.72 rad/s versus 125.66 rad/s at 1,200 rpm. Force scales with ω², so the replacement generated approximately (104.72²/125.66²) = 69% of the original force. Amplitude measurement confirmed reduced stroke. The replacement’s static moment was higher to partially compensate, but not enough to match the original force output.
Result: Original specification exciter sourced at the correct speed rating. Amplitude returned to commissioning baseline. Cost of the investigation was minor compared to a potential structural upgrade or process redesign to accommodate the reduced force. The plant added a calculation verification step to the exciter replacement procedure.
Figures reflect a realistic single-site investigation and are not a guaranteed performance claim.
FAQ
Q1: Is exciting force the same as centrifugal force?
They are closely related in an unbalanced-mass exciter but describe different aspects. Centrifugal force is generated by rotating eccentric masses and is calculated as F_0 = M_s × ω². The screen’s required dynamic force relates to the mass being accelerated and the complete system response. In a preliminary estimate, inertial force is M_v × K × g.
Q2: How do I calculate exciting force if the screen stroke is known?
First convert stroke to peak amplitude: A = S/2. Convert rotational speed to angular velocity using ω = 2πn/60. For approximately sinusoidal motion, calculate peak acceleration as a = A × ω², then express as K = a/g. If effective vibrating mass is known, the preliminary inertial-force estimate is F ≈ M_v × a.
Q3: Does increasing exciter speed always increase exciting force?
At constant static moment, centrifugal-force amplitude is proportional to the square of angular speed. Increasing speed by 10% increases theoretical force by about 21%. However, speed also changes operating frequency and dynamic response. Never increase speed beyond the screen or exciter manufacturer’s approved operating range.
Q4: How should exciting force be divided between two linear exciters?
For two identical exciters in a correctly synchronized linear-motion arrangement, force components in the intended direction add while transverse components cancel. If symmetrical and load sharing is equal, each may be sized for approximately half the total. This is not universal — shaft geometry, phase and the manufacturer’s force-rating convention must be checked.
Q5: Can I select an exciter using exciting force alone?
No. Exciting force is only one parameter. The exciter must also match required speed, static or working moment, motion type, bearing loads, bearing life, shaft strength, lubrication, mounting dimensions and operating environment. Springs, support structure and fatigue strength must also be verified.
Q6: How much does it cost to correct an incorrect exciter selection?
The cost depends on the error. An exciter at the wrong speed may require replacement plus lost production during correction. An exciter with wrong static moment may require weight adjustment if the design permits, or replacement if not. A force calculation review is a minor cost compared to any of these outcomes.
Q7: Why is the effective vibrating mass different from the screen’s total mass?
The screen body is supported by springs and the material on the deck is continuously moving and discharging. Not all of the machine or material participates in the vibration as a rigid body. Using total mass substantially overestimates the force requirement, producing an oversized exciter that wastes energy and stresses the structure unnecessarily.
Q8: What is the difference between static moment and working moment?
Static moment is the geometric property Σ(m_i × r_i). Working moment may account for the actual operating arrangement, weight position and phase relationship. Some catalogues use these terms interchangeably, others distinguish them. Always check the definition in the specific catalogue before sizing.
Q9: How do I convert kg·cm to kg·m?
Divide by 100. 1 kg·m = 100 kg·cm. This is a common source of error because some catalogues quote one unit and some the other. Always verify which unit the catalogue uses before comparing values.
Q10: Should the calculation consider the material load on the deck?
Yes, but only a defined portion. The material moving on the deck contributes to the vibrating mass, but not the full throughput. The designer’s method, operating data or validated dynamic model should establish the effective material mass contribution. Treating full throughput as vibrating mass overestimates the requirement.
Conclusion
The preliminary exciting-force calculation starts with effective vibrating mass and target acceleration: F ≈ M_v × K × g. The force generated by unbalanced weights is calculated from static moment and angular speed: F_0 = M_s × ω². By converting rpm to rad/s, resolving force vectors and comparing required static moment with the exciter’s rated range, engineers can make an initial sizing assessment.
The key is to treat this as a connected dynamic-system calculation — not merely a multiplication exercise. Confirm the mass basis, distinguish amplitude from stroke, account for exciter arrangement, and verify spring, damping, bearing and structural limits before selecting, replacing or adjusting an exciter.
If you are sizing or replacing an exciter, HTL can review your application details and operating requirements.
Related Articles
Related Products
Related Technical Guides
-
IMPROVE FINE SCREENING EFFICIENCY WITH POLYURETHANE SCREEN PANELS
-
HYDROCYCLONE WEAR: ROOT CAUSES, HIGH-WEAR ZONES & MATERIAL SOLUTIONS
-
FLOTATION CELL ROTOR AND STATOR WEAR PARTS: HOW THEY CONTROL RECOVERY, FLOW AND MAINTENANCE COST
-
ROTOR & STATOR IN MECHANICAL FLOTATION CELLS: THE HEART OF EFFICIENT MINERAL FLOTATION
Related Buyer Guides
-
WHICH MANUFACTURER OFFERS HIGH-QUALITY POLYURETHANE TUFFLEX WIRE SCREENS FOR MINING?
-
HOW DO I CHOOSE THE RIGHT RUBBER BELT FOR A VACUUM BELT FILTER?
Related Comparison Articles
-